Product manual
Product applications, preparation, use and storage requirements.
A pH-responsive labeling reagent for human-antibody internalization studies, detecting fluorescence changes after entry into acidic compartments.
Packs & quoteFluorescence increases as the environment becomes acidic. Signal depends on antibody and reagent amounts, uptake, local pH and acquisition settings. Keep reagent ratios, sample amounts and instrument settings consistent across comparisons.
Compare target-positive and target-negative samples over time. Assess antibody binding activity alongside fluorescence to evaluate receptor-mediated internalization.
Select channels using actual excitation and emission peaks and filter bandwidths. Use single-color controls to assess spillover and keep gain settings consistent.
Use the dedicated manual to confirm antibody compatibility and labeling conditions.
Confirm the human-antibody type, formulation components and assay compatibility, and follow this reagent’s specific labeling instructions.
Include unlabeled antibody, target-negative samples and reagent blanks. Confirm that labeling preserves antibody binding before comparing internalization.
Keep sample handling and acquisition settings consistent. Record fluorescence and intracellular localization over time, with acidification controls when needed.
Choose a document and enter your phone and email. Include the product lot number when requesting a CoA.
Product applications, preparation, use and storage requirements.
Test items and results for the corresponding lot.
Safe handling, storage and emergency-response information.
Compare detection channels and labeling routes for pHAb, pH560 Red, pH630 Deep Red and the human-antibody companion reagent, with channel and sample considerations for internalization assays.
Check the QH-17-1003 liquid formulation, antibody compatibility and background controls without applying a free-dye workflow.
Separate target-mediated uptake, nonspecific uptake and acidification, and define what the fluorescence readout measures.
Localize the problem through cell-free response, binding and cellular readouts before increasing dye or antibody amounts.
Methods and application studies using the reagents identified in each paper; these are not validation data for Qihe products.
Jin H, et al. · Oncoimmunology · 10(1):1958590 · 2021
Separates contributions from Fcγ-receptor binding and PD-L1 binding to antibody internalization.
DOI: 10.1080/2162402X.2021.1958590
Liao-Chan S, et al. · PLoS One · 10(4):e0124708 · 2015
Tracks antibody internalization by separating surface and intracellular fluorescence, without relying on acid-dependent brightening.
DOI: 10.1371/journal.pone.0124708
This reagent is intended for human-antibody labeling. The name “anti-human” does not establish compatibility with every IgG subclass or fragment. Include species, subclass, antibody format and formulation when requesting information for a specific sample.
Read the technical guide →First mix it with the test antibody using the dedicated workflow, then prepare the cell-assay working solution. Include a reagent-only control without test antibody to assess reagent-associated background.
Read the technical guide →630 is the family name. The listed excitation/emission wavelengths are 640/655 nm. Check the actual laser line and far-red emission filter rather than choosing a channel from the name alone.
Read the technical guide →No. It is supplied as 200 μL of liquid at 0.5 mg/mL. Mix gently without sonication and prepare the labeling mixture using its dedicated instructions. Do not use a preparation procedure for powdered TFP, NHS Ester or maleimide dyes.
Read the technical guide →Yes. The stock contains 50% glycerol, so account for its final concentration after dilution. Keep reagent ratios and total volumes consistent when comparing antibodies, and use a matched reagent control to assess background and cell health.
Read the technical guide →Store at −20°C, protected from light, and avoid repeated freeze–thaw cycles. Keep opened reagent sealed as instructed. Stock storage conditions do not establish the shelf life of diluted working solutions.
First check the channel, antibody binding and cell health, and compare the complete mixture with a reagent-only control. More reagent may also increase background. Establish whether the issue is the antibody, labeling system or detection settings first.
Read the technical guide →Not necessarily. Local pH, antibody and reagent amounts, and cell number also affect the signal. Keep reagent ratios consistent and check binding activity when comparing antibodies. Add an independent localization or uptake readout to distinguish uptake from acidification.
Read the technical guide →Do not assume that processing preserves the original pH readout. Fixation, permeabilization and medium exchange can alter the probe environment. Measure live cells when studying live-cell internalization; if fixation is required, first compare response and localization before and after processing.
Read the technical guide →Request the manual with your antibody format and assay details.