Which groups are on your target?
Consider NHS for primary amines and Maleimide for free thiols. For click chemistry, confirm the reaction partners first.
Near-infrared emission, with 5 reactive dyes and 3 bioconjugates. Excitation near 785 nm and collection above 800 nm; find labeling methods and documents for the target handle.
Optical values refer to AF790 NHS.

Find AF790 dyes and conjugates by reactive group or recognition ligand.
Consider NHS for primary amines and Maleimide for free thiols. For click chemistry, confirm the reaction partners first.
Compare Annexin V, WGA, CTB; check the sample and conditions.
| Product / catalog no. | Reactive form / ligand | Targets and applications | Documents |
|---|---|---|---|
| AF790 NHS EsterQH-10-1016 | NHS | Antibodies, proteins and other molecules with accessible primary amines | View product → |
| AF790 MaleimideQH-10-1016(Maleimide) | Maleimide | Targets with accessible free thiols | View product → |
| AF790 AzideQH-10-1016(Azide) | Azide | Targets with a compatible alkyne; confirm the click reaction system | View product → |
| AF790-PEG4-DBCOQH-10-1016(DBCO PEG4) | PEG4-DBCO | Azide coupling with a PEG4 spacer | View product → |
| AF790-PEG12-DBCOQH-10-1016(DBCO PEG12) | PEG12-DBCO | Azide coupling; evaluate a PEG12 spacer | View product → |
| AF790-Annexin VQH-10-1016(Annexin V) | Annexin V | Recognizes exposed PS; binding requires Ca²⁺ | View product → |
| AF790 WGAQH-10-1016(WGA) | WGA | Recognizes glycans containing GlcNAc or sialic acid | View product → |
| AF790 CTBQH-10-1016(CTB) | CTB | Recognizes GM1; consider binding and uptake conditions | View product → |
Showing 8 / 8 AF790 products
Values refer to this product’s specifications. Consult measurement records for solvent, pH and conjugation state.
Full product specifications →A 785 nm source lies near the excitation peak and requires optics and a detector suitable for signals above 800 nm. Check laser leakage, filter blocking and camera quantum efficiency rather than carrying over visible-dye gain assumptions.
A 820/40 bandpass nominally spans 800–840 nm and includes the 810 nm emission peak. Collected signal depends on the full emission spectrum, filter transmission and detector response; this is a passband example. An 800 nm longpass designation does not establish efficient collection of all emission; the filter edge and detector response matter.
Read the detection guide →AF790 and AF750 occupy adjacent near-infrared emission regions, and broad windows can mix their signals. Measure each label with the intended sources and channels, including dye-free samples to assess background at long exposures.
Multicolor detection considerations →For established recognition ligands, review the corresponding conjugates and their product-specific formulation, dose and storage conditions.
| Product | Recognition target and conditions |
|---|---|
| AF790-Annexin V | Phosphatidylserine; binding is Ca²⁺ dependent. |
| AF790 WGA | GlcNAc- or sialic-acid-containing glycans; consider sample preparation and intracellular signal. |
| AF790 CTB | GM1 ganglioside; confirm the application and treatment conditions. |
References on reaction chemistry, assay design and result interpretation.
Nanda JS, Lorsch JR. · Methods in Enzymology · 536:87–94 · 2014
Uses FAM ester labeling of a protein to explain primary-amine chemistry and labeling-efficiency assessment. It informs NHS workflow design; input and reaction conditions depend on the actual dye and sample.
Vira S, Mekhedov E, Humphrey G, Blank PS. · Analytical Biochemistry · 402(2):146–150 · 2010
Uses FITC-labeled anti-HA antibody to assess changes in labeling density and antigen binding. It informs input-series design and post-purification functional testing; DOL alone is insufficient for selecting a conjugate.
Cossarizza A, Chang HD, Radbruch A, et al. · European Journal of Immunology · 51(12):2708–3145 · 2021
Provides methodological guidance on detection settings, controls and experimental records for downstream conjugate evaluation.
AF790 NHS has an excitation peak of 785 nm and an emission peak of 810 nm. Check the product name, source wavelength and collection window separately. A 785 nm source lies near the excitation peak and requires optics and a detector suitable for signals above 800 nm. Check laser leakage, filter blocking and camera quantum efficiency rather than carrying over visible-dye gain assumptions.
A 820/40 bandpass nominally spans 800–840 nm and includes the 810 nm emission peak. Collected signal depends on the full emission spectrum, filter transmission and detector response; this is a passband example. An 800 nm longpass designation does not establish efficient collection of all emission; the filter edge and detector response matter.
The peak-position figure cannot compare brightness or calculate compensation. Use measured spectra to inspect filter coverage, then unstained and single-stain samples to assess background and signal. Keep gain or exposure fixed when comparing samples.
chroma.com
tools.thermofisher.com
AF790 and AF750 occupy adjacent near-infrared emission regions, and broad windows can mix their signals. Measure each label with the intended sources and channels, including dye-free samples to assess background at long exposures.
Measure each single-stain sample in every relevant channel and use an unstained sample for baseline fluorescence. Set conventional-flow compensation from these measurements or use dye- and treatment-matched references for spectral unmixing. If signals remain poorly resolved, change the dye panel or detection windows.
When comparing dye conjugates of the same target, match target concentration and labeling density and record each source and filter. A brighter reading in one channel may reflect better excitation or collection. Compare specific signal, background, recovery and function alongside raw intensity.
Cossarizza A, Chang HD, Radbruch A, et al. · European Journal of Immunology · 51(12):2708–3145 · 2021
chroma.com
NHS labels primary amines; maleimide labels free thiols. Additives and reduction requirements determine sample preparation.
Terminal alkynes pair with azides through CuAAC; DBCO pairs with azides through copper-free SPAAC.
Compare labeling density, sample recovery, specific signal and background after purification, rather than total fluorescence alone.
Instructions, SDS, product specifications and CoA are catalog-specific. Request documents on the corresponding product page and include the vial lot number for a CoA.
QH-10-1016
QH-10-1016(Maleimide)
QH-10-1016(Azide)
QH-10-1016(DBCO PEG4)
QH-10-1016(DBCO PEG12)
QH-10-1016(Annexin V)
QH-10-1016(WGA)
QH-10-1016(CTB)
Include the target, reactive handles, buffer formulation, excitation source and emission window to help identify the product and supporting measurement information.
AF790 NHS has an excitation peak of 785 nm and an emission peak of 810 nm. Check the product name, source wavelength and collection window separately.
It does not establish application validation. Distribution, clearance, tissue background and target function require separate study. Establish conjugation and purification for the reactive handle before evaluating signal and behavior in the intended application.
AF790 and AF750 occupy adjacent near-infrared emission regions, and broad windows can mix their signals. Measure each label with the intended sources and channels, including dye-free samples to assess background at long exposures.
Use NHS for primary amines, Maleimide for free thiols, Azide for terminal or strained alkynes, and PEG4-DBCO or PEG12-DBCO for azides. Each product page covers pretreatment, buffer and purification requirements.
Follow each product page and vial label. Reactive dyes in this catalog are stored dry at −20°C and protected from light; aqueous conjugates have separate requirements. Prepared dye solutions and newly made conjugates cannot simply inherit dry-dye storage conditions.
Do not borrow these values. Reactive form, spacer, structure and salt form can affect them; confirm by catalog number. Request missing identity and calculation parameters through the product Documents tab rather than inferring them from a similar name.
Use Documents on the specific product page and describe the application and detection settings. Supply the catalog and vial lot numbers for a CoA. The displayed spectrum is a peak schematic and references concern methods; neither is a lot inspection result.