Assay Kits

23 product(s) found. Click a product name to view detailed specifications and pricing.

Excitation 310–787 nm, emission 410–808 nm

Wavelength

Cell-Life Dye Fixable Cell Viability Staining Kit

Cell-Life Dye 330/410

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 350/450

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 375/600

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 405/450

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 405/510

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 405/540

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 488/520

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 510/550

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 568/583

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 594/614

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 633-647/710

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 633/740

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 633/780

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 642/662

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View
Cell-Life Dye 787/808

Cell-Life Dye Series is a high-performance viability staining reagent, can specifically label dead cells, widely used in flow cytometry and fluorescent microscopy imaging experiments, help accurately eliminate the interference of dead cells.

Live/dead cell discriminationFlow cytometry
Request quote
View

Label IT Reagent Nucleic Acid Labeling Kit

Label IT Fluorescein Labeling Kit

Label IT Nucleic Acid Labeling Technology is a technology designed to efficiently, scalably and reproducibly attach labeling molecules to any nucleic acid sample in one step. and with its non-radioactive labeling technology(such as random primer method, nick translation method)different from, Label IT Nucleic Acid Labeling Reagent can significantly altering the starting nucleic acids or hindering downstream hybridization performance, can covalently link CX-Rhodamine, Fluorescein, MFP488, Digoxigenin, Biotin, Cy3, Cy5, Dinitrophenol (DNP) or TM-Rhodamine to the bases of DNA or RNA. Since the Label IT reaction is non-destructive to the starting nucleic acid material, Label IT Technology can be used for various in vivo, in vitro and molecular biology applications.

Nucleic acid labelingFISHMicroarrays
Request quote
View
Label IT Cy3 Labeling Kit

Label IT Nucleic Acid Labeling Technology is a technology designed to efficiently, scalably and reproducibly attach labeling molecules to any nucleic acid sample in one step. and with its non-radioactive labeling technology(such as random primer method, nick translation method)different from, Label IT Nucleic Acid Labeling Reagent can significantly altering the starting nucleic acids or hindering downstream hybridization performance, can covalently link CX-Rhodamine, Fluorescein, MFP488, Digoxigenin, Biotin, Cy3, Cy5, Dinitrophenol (DNP) or TM-Rhodamine to the bases of DNA or RNA. Since the Label IT reaction is non-destructive to the starting nucleic acid material, Label IT Technology can be used for various in vivo, in vitro and molecular biology applications.

Nucleic acid labelingFISHMicroarrays
Request quote
View
Label IT Cy5 Labeling Kit

Label IT Nucleic Acid Labeling Technology is a technology designed to efficiently, scalably and reproducibly attach labeling molecules to any nucleic acid sample in one step. and with its non-radioactive labeling technology(such as random primer method, nick translation method)different from, Label IT Nucleic Acid Labeling Reagent can significantly altering the starting nucleic acids or hindering downstream hybridization performance, can covalently link CX-Rhodamine, Fluorescein, MFP488, Digoxigenin, Biotin, Cy3, Cy5, Dinitrophenol (DNP) or TM-Rhodamine to the bases of DNA or RNA. Since the Label IT reaction is non-destructive to the starting nucleic acid material, Label IT Technology can be used for various in vivo, in vitro and molecular biology applications.

Nucleic acid labelingFISHMicroarrays
Request quote
View

EdU Series Cell Proliferation Detection Kit

EdU-488 Cell Proliferation Detection Kit

EdU Series Cell Proliferation Detection Kit can detect individual proliferating cells in cells, tissue samples and tissue sections, and can quantitatively analyze the overall cell proliferation of these samples, including cultured cell and tissue samples, suitable for fluorescence microscope, laser confocal microscope, flow cytometer, fluorescence microplate reader detection and High-Content Screening (HCS)(High-Content Screening, HCS).

Cell proliferation assaysClick chemistryFlow cytometry
Request quote
View
EdU-555 Cell Proliferation Detection Kit

EdU Series Cell Proliferation Detection Kit can detect individual proliferating cells in cells, tissue samples and tissue sections, and can quantitatively analyze the overall cell proliferation of these samples, including cultured cell and tissue samples, suitable for fluorescence microscope, laser confocal microscope, flow cytometer, fluorescence microplate reader detection and High-Content Screening (HCS)(High-Content Screening, HCS).

Cell proliferation assaysClick chemistryFlow cytometry
Request quote
View
EdU-594 Cell Proliferation Detection Kit

EdU Series Cell Proliferation Detection Kit can detect individual proliferating cells in cells, tissue samples and tissue sections, and can quantitatively analyze the overall cell proliferation of these samples, including cultured cell and tissue samples, suitable for fluorescence microscope, laser confocal microscope, flow cytometer, fluorescence microplate reader detection and High-Content Screening (HCS)(High-Content Screening, HCS).

Cell proliferation assaysClick chemistryFlow cytometry
Request quote
View
EdU-647 Cell Proliferation Detection Kit

EdU Series Cell Proliferation Detection Kit can detect individual proliferating cells in cells, tissue samples and tissue sections, and can quantitatively analyze the overall cell proliferation of these samples, including cultured cell and tissue samples, suitable for fluorescence microscope, laser confocal microscope, flow cytometer, fluorescence microplate reader detection and High-Content Screening (HCS)(High-Content Screening, HCS).

Cell proliferation assaysClick chemistryFlow cytometry
Request quote
View

pH Dye Antibody Labeling Kit - for Human Antibody Internalization Detection

pH630 Deep Red anti-human labeling reagent

pH630 Deep Red anti-human labeling reagent enables rapid, scalable and efficient internalization labeling of antibodies. These pH-sensitive dye conjugates have unique fluorescent properties: almost no fluorescence in the extracellular environment, once entering the acidic environment such as phagosomes, it will immediately emit bright red fluorescence. With this property, compared with other phagocytosis assay methods, this labeling reagent can capture signals faster and reflect experimental results more accurately, significantly improve the efficiency and accuracy of phagocytosis detection.

Antibody labelingInternalization studiesPhagocytosis assays
Request quote
View

We use cookies and third-party analytics (Microsoft Clarity, Baidu Tongji, Google Analytics) to measure traffic and improve our service. Clarity includes session recording. You may decline — core site functionality is unaffected. View privacy policy